RadSum23
Models write the impression section of radiology reports from findings. One track includes chest images. Organizers rank submissions by RadGraph F1.
The shs-nlp team adapted BLOOMZ for the challenge. MIMIC data require signed PhysioNet agreements. The hidden chest test includes Stanford cases.
- Made by
- Stanford University
- Released
- January 2023
- Kind
- Medicine
- Level
- Expert
- Scored
- Checked automatically
- Answers
- Open-ended
- Tasks
- Kept private
- Measures
- Capability
- Subject
- Clinical medicine
- Language
- English
- Interaction
- Single turn
- Items from
- Real work and use, Another benchmark
- Refresh
- One fixed set
- Run by
- A host
- In views
- Vision, Biology and medicine
- Updated automatically
- No, from its paper
- Scores refreshed
- November 20th, 2026
In the authors’ words
Radiology report summarization is a growing area of research. Given the Findings and/or Background sections of a radiology report, the goal is to generate a summary (called an Impression section) that highlights the key observations and conclusions of the radiology study. Recent efforts have released systems that achieve promising performance as measured by widely used summarization metrics such as BLEU and ROUGE. However, the research area of radiology report summarization currently faces two important limitations. First, most of the results are reported on private datasets. This limitation prevents the ability to reproduce results and fairly compare different systems and solutions. Secondly, to the best of our knowledge, most research is carried out on chest X-rays. To palliate these two limitations, we propose a radiology report summarization (RadSum) challenge on i) a new dataset of eleven different modalities and anatomies pairs based on the MIMIC-III database ii) a multimodal report summarization dataset based on MIMIC-CXR enhanced with a brand-new test-set from Stanford Hospital. In total, we received 112 submissions across 11 teams.
RadBloomz tops the leaderboard with 39.8 T5-Base leads with 38.0
Best score per entry from the benchmark's paper, read on November 20th, 2026. A paper’s table doesn’t add newer models. The papers report no overall score, so the headline is the plain mean of F1-RadGraph across the four test sets. Where a model ran with several settings or harnesses, we keep its best. Names in gray aren't in our model list: fine-tunes, agent systems, products and older models. They don't count toward leaders. The best model we track is T5-Base, at 38.0. This view shows only models we track, each at its best.
- 1 RadBloomz Zero-shot 39.8
- 2 BART Fine-tuned on MIMIC-III with further fine-tuning for MIMIC-CXR 38.0
- 3 T5-Base Fine-tuned on MIMIC-III with further fine-tuning for MIMIC-CXR 38.0
Source: The RadSum23 paper
Source: The RadSum23 paper
| # | Entry | Score | Setting | Submitted by | Date | Source |
|---|---|---|---|---|---|---|
| 1 | RadBloomz | 39.8 | Zero-shot | shs-nlp | Official leaderboard | |
| 2 | BART | 38.0 | Fine-tuned on MIMIC-III with further fine-tuning for MIMIC-CXR | KnowLab | Official leaderboard | |
| 3 | T5-Base | 38.0 | Fine-tuned on MIMIC-III with further fine-tuning for MIMIC-CXR | KnowLab | Official leaderboard |
| # | Model | Score | Setting | Submitted by | Date | Source |
|---|---|---|---|---|---|---|
| 1 | T5-Base | 38.0 | Fine-tuned on MIMIC-III with further fine-tuning for MIMIC-CXR | KnowLab | Official leaderboard |
Everything the board measures
The benchmark’s paper publishes 19 numbers for each entry: the headline score, 4 parts of the test and 14 other measures. Rank entries by any one, compare them all in the table, or plot any two. Each row is the entry’s best run on the headline score.
- Headline
- Headline score
- Parts
- MIMIC-III test set
- MIMIC-III hidden test set
- MIMIC-CXR test set
- MIMIC-CXR hidden test set
- Other measures
- MIMIC-III open BLEU4
- MIMIC-III open ROUGE-L
- MIMIC-III open BERTScore
- MIMIC-III hidden BLEU4
- MIMIC-III hidden ROUGE-L
- MIMIC-III hidden BERTScore
- MIMIC-CXR open BLEU4
- MIMIC-CXR open ROUGE-L
- MIMIC-CXR open BERTScore
- MIMIC-CXR open F1 CheXbert
- MIMIC-CXR hidden BLEU4
- MIMIC-CXR hidden ROUGE-L
- MIMIC-CXR hidden BERTScore
- MIMIC-CXR hidden F1 CheXbert
Nothing matches.
- Headline
- Headline score
- Parts
- MIMIC-III test set
- MIMIC-III hidden test set
- MIMIC-CXR test set
- MIMIC-CXR hidden test set
- Other measures
- MIMIC-III open BLEU4
- MIMIC-III open ROUGE-L
- MIMIC-III open BERTScore
- MIMIC-III hidden BLEU4
- MIMIC-III hidden ROUGE-L
- MIMIC-III hidden BERTScore
- MIMIC-CXR open BLEU4
- MIMIC-CXR open ROUGE-L
- MIMIC-CXR open BERTScore
- MIMIC-CXR open F1 CheXbert
- MIMIC-CXR hidden BLEU4
- MIMIC-CXR hidden ROUGE-L
- MIMIC-CXR hidden BERTScore
- MIMIC-CXR hidden F1 CheXbert
Nothing matches.
- Headline
- Headline score
- Parts
- MIMIC-III test set
- MIMIC-III hidden test set
- MIMIC-CXR test set
- MIMIC-CXR hidden test set
- Other measures
- MIMIC-III open BLEU4
- MIMIC-III open ROUGE-L
- MIMIC-III open BERTScore
- MIMIC-III hidden BLEU4
- MIMIC-III hidden ROUGE-L
- MIMIC-III hidden BERTScore
- MIMIC-CXR open BLEU4
- MIMIC-CXR open ROUGE-L
- MIMIC-CXR open BERTScore
- MIMIC-CXR open F1 CheXbert
- MIMIC-CXR hidden BLEU4
- MIMIC-CXR hidden ROUGE-L
- MIMIC-CXR hidden BERTScore
- MIMIC-CXR hidden F1 CheXbert
Nothing matches.
Scores over time
All the scores we have, one dot each, so a model tested at several settings appears more than once.
No dated values yet.
No lab model card reports it yet
We read the headline results of 546 launch posts from 59 labs, and none of them list this benchmark.
More in Law, finance and medicine
- MedXpertQA-MM In use Models answer expert-level medical exam questions that combine images with clinical records and test results. Scoring is accuracy.
Qwen 3.8 Max 80.4%
- HealthBench Professional In use 525 physician-authored tasks from real clinician chats (care consult, documentation, research) with physician-adjudicated rubrics. Claude Sonnet 5.5 69.2%
- HealthBench In use 5,000 realistic health conversations graded against physician-written rubrics. A length-adjusted variant penalizes verbosity. GPT-5 67.2%
- FinSearchComp In use Agents search the web to fetch live financial data, look up history, and run multi-step investigations, across 635 expert-written questions. Scored by answer accuracy.
Ling-3.1-flash 81.7%
- KorMedMCQA In use Models answer 7,469 multiple-choice questions from Korean licensing exams for doctors, nurses, pharmacists and dentists, held from 2012 to 2024. o1-preview 92.7%
- Harvey LAB-AA v1.1 In use Artificial Analysis's run of Harvey's Legal Agent Benchmark on Harvey's newer private set of 120 tasks across 24 practice areas. A deliverable with a material hallucination scores zero, and the headline is the share of judges who find every rubric criterion passed. GPT-6.2 Astra 15%
Data audit
All 7 checks pass. Every benchmark
Catalog record 2 pass
- Pass Task access The tasks are private.
- Pass Confidence Checked against a primary source.
Scores 1 pass 4 notes
- Pass Independent runs Scores from the benchmark’s paper (3 entries).
- Note Models scored Only 1 model we track, plus 2 other entries on its leaderboard.
- Note Newest score No scores yet.
- Note Frontier models None of its models are on the capabilities index.
- Note Headroom Scored as a plain number, with no fixed ceiling.
Leaderboard import 3 pass
- Pass Importer We read the board on aclanthology.org: 1 row for models we track and 2 other entries at the last read.
- Pass Last read November 20th, 2026.
- Pass Read worked The last read worked.
Consistency 1 pass 2 notes
- Note Lab claims No model has both a lab number and an independent run.
- Pass Known issues No published audit found problems.
- Note Epoch AI review Epoch AI hasn’t reviewed it.