Benchmark Almanac

MIMIC-CXR report generation

Med-PaLM M 84B 26.7% tops its leaderboard
Not in model cards

Models write the findings of a radiology report for a MIMIC-CXR chest X-ray. Scored against the radiologist's report, most often by RadGraph F1.

Google reports RadGraph F1 on a 912-image test set from Tanno et al. (2024). Other reports use other splits and metrics, so check the split before comparing.

Released
January 2019
Kind
Medicine
Level
Expert
Scored
Checked automatically
Answers
Open-ended
Tasks
All public
Measures
Capability
Language
English
In and out
Text, Images → Text
Interaction
Single turn
Refresh
One fixed set
Run by
Anyone
Updated automatically
Yes, daily

In the authors’ words

Chest radiography is an extremely powerful imaging modality, allowing for a detailed inspection of a patient's thorax, but requiring specialized training for proper interpretation. With the advent of high performance general purpose computer vision algorithms, the accurate automated analysis of chest radiographs is becoming increasingly of interest to researchers. However, a key challenge in the development of these techniques is the lack of sufficient data. Here we describe MIMIC-CXR-JPG v2.0.0, a large dataset of 377,110 chest x-rays associated with 227,827 imaging studies sourced from the Beth Israel Deaconess Medical Center between 2011 - 2016. Images are provided with 14 labels derived from two natural language processing tools applied to the corresponding free-text radiology reports. MIMIC-CXR-JPG is derived entirely from the MIMIC-CXR database, and aims to provide a convenient processed version of MIMIC-CXR, as well as to provide a standard reference for data splits and image labels. All images have been de-identified to protect patient privacy. The dataset is made freely available to facilitate and encourage a wide range of research in medical computer vision.

Abstract of MIMIC-CXR-JPG, a large publicly available database of labeled chest radiographs (arXiv:1901.07042, CC0)
2
Entries on SOTA2 Research’s leaderboard, 0 models we track

Med-PaLM M 84B tops the leaderboard with 26.7%

Best score per entry from SOTA2 Research’s leaderboard, read on November 24th, 2026. The all-views leaderboard reports RadGraph F1 for the test cohort named in each setting. Where a model ran with several settings or harnesses, we keep its best. Names in gray aren't in our model list: fine-tunes, agent systems, products and older models. They don't count toward leaders.

  1. 1 Med-PaLM M 84B All views, test set size 4,834 26.7%
  2. 2 M4CXR All views, test set size 3,858 21.7%

Source: SOTA2 Research’s leaderboard

#EntryScoreSettingDateLinkSource
1 Med-PaLM M 84B 26.7% All views, test set size 4,834 sota2.com Official leaderboard
2 M4CXR 21.7% All views, test set size 3,858 sota2.com Official leaderboard

No lab model card reports it yet

We read the headline results of 546 launch posts from 59 labs, and none of them list this benchmark.

More in Law, finance and medicine

All 638 in Law, finance and medicine
  • MedXpertQA-MM In use Models answer expert-level medical exam questions that combine images with clinical records and test results. Scoring is accuracy. Qwen 3.8 Max 80.4%
  • HealthBench Professional In use 525 physician-authored tasks from real clinician chats (care consult, documentation, research) with physician-adjudicated rubrics. Claude Sonnet 5.5 69.2%
  • HealthBench In use 5,000 realistic health conversations graded against physician-written rubrics. A length-adjusted variant penalizes verbosity. GPT-5 67.2%
  • FinSearchComp In use Agents search the web to fetch live financial data, look up history, and run multi-step investigations, across 635 expert-written questions. Scored by answer accuracy. Ling-3.1-flash 81.7%
  • KorMedMCQA In use Models answer 7,469 multiple-choice questions from Korean licensing exams for doctors, nurses, pharmacists and dentists, held from 2012 to 2024. o1-preview 92.7%
  • Harvey LAB-AA v1.1 In use Artificial Analysis's run of Harvey's Legal Agent Benchmark on Harvey's newer private set of 120 tasks across 24 practice areas. A deliverable with a material hallucination scores zero, and the headline is the share of judges who find every rubric criterion passed. GPT-6.2 Astra 15%

Data audit

All 7 checks pass. Every benchmark

Catalog record 2 pass
  • Pass Task access All tasks are public.
  • Pass Confidence Checked against a primary source.
Scores 1 pass 4 notes
  • Pass Independent runs Scores from the official leaderboard (2 entries).
  • Note Models scored 2 entries on its leaderboard, none a model we track.
  • Note Newest score No scores yet.
  • Note Frontier models No models scored yet.
  • Note Headroom No scores yet.
Leaderboard import 3 pass
  • Pass Importer We read the board on SOTA2 Research: 2 entries at the last read, none a model we track.
  • Pass Last read November 24th, 2026.
  • Pass Read worked The last read worked.
Consistency 1 pass 2 notes
  • Note Lab claims No model has both a lab number and an independent run.
  • Pass Known issues No published audit found problems.
  • Note Epoch AI review Epoch AI hasn’t reviewed it.

How we check